Antec EarthWatts EA 380D Green 380W
Efficiency & PFC
| 230VAC, 50Hz | ||
| Load | Efficiency | PFC |
| 10% | 77.69% | 0.858 |
| 20% | 84.99% | 0.891 |
| 50% | 87.58% | 0.936 |
| 80% | 85.56% | 0.951 |
| 100% | 84.30% | 0.958 |
| 110% | 83.28% | 0.964 |
| 115VAC, 60Hz | ||
| Load | Efficiency | PFC |
| 10% | 79.34% | 0.916 |
| 20% | 84.03% | 0.969 |
| 50% | 85.58% | 0.973 |
| 80% | 83.87% | 0.978 |
| 100% | 82.61% | 0.981 |
| 110% | 81.12% | 0.984 |
The sample reaches just 78% efficiency at 10% load, but at all other loads it's above 80%. The peak efficiency on 230VAC is 87.58%. At higher loads it slightly decreases and 83-84% is reached at full load. These are common results. The power factor reaches between 0.858 and 0.964. If we switch to 115VAC, the power factor always stays above 0.900 with a maximum of 0.984.