Antec EarthWatts EA 380D Green 380W
Voltage Regulation
| +3.3V regulation | |
| Load | Voltage |
| 10% | 3.34V (+1.21%) |
| 20% | 3.33V (+0.91%) |
| 50% | 3.31V (+0.30%) |
| 80% | 3.30V (0%) |
| 100% | 3.28V (-0.61%) |
| 110% | 3.28V (-0.61%) |
| +5V regulation | |
| Load | Voltage |
| 10% | 5.01V (+0.2%) |
| 20% | 4.99V (-0.2%) |
| 50% | 4.97V (-0.6%) |
| 80% | 4.95V (-1%) |
| 100% | 4.92V (-1.6%) |
| 110% | 4.90V (-2%) |
| +12V regulation | |
| Load | Voltage V1 / V2 |
| 10% | 12.03V / 12.02V (+0.25 / +0.17%) |
| 20% | 12.04V / 12.03V (+0.33% / +0.25%) |
| 50% | 12.02V / 12.02V (+0.17% / +0.17%) |
| 80% | 12.00V / 11.99 V (0% / -0.08% ) |
| 100% | 11.97V / 11.96 (-0.25% / -0.33%) |
| 110% | 11.95V / 11.94V (-0.42% / -0,5%) |
The voltage drops are minor at all loads. +12V slightly rises at 20% load to work against the voltage drop at higher currents. With 4.90V the +5V rails reaches its highest drop at 12.56A and ranges just above the nominal value at 10%. At similar loads +3.3V rail reaches 3.28V. Both +12V rails are within specification and show a nearly identical trend. 11.94V is the lowest value at 110% load (13.49A on the bigger rail). Even if you overclock, you won’t fall below tolerance on a single wire of the CPU connector.