Archive 1997–2024

Antec TruePower Quattro 1200W

Efficiency and PFC

230VAC, 50Hz
Load Efficiency PFC
10% 79.21% 0.885
20% 87.98% 0.975
50% 90.67% 0.989
80% 89.99% 0.989
100% 88.62% 0.995
110% 87.70% 0.995

 

120VAC, 60Hz
Load Efficiency PFC
10% 78.17% 0.981
20% 85.19% 0.990
50% 88.67% 0.996
80% 87.06% 0.996
100% 85.15% 0.997
110% 84.04% 0.999

The Antec 1200W efficiency is not outstanding, but it's still very high and reaches 91% at 50% and 230VAC. With 115VAC the maximum efficiency is 89%, more than acceptable for practical use. Another interesting fact is that the TruePower nearly attained 80% at low load. With 83% the Seasonic X-Series was a little bit better here, but 80% is still a positive and unusual result for 10%. On one hand they can’t establish a record here. On the other hand, PFC was often over 0.975, even at 230VAC. And 0.999 is an impressive result as well. With 90VAC Antec reached up to 87.14% efficiency at 50% load.

Originally published at https://www.anandtech.com/show/3807/antec-truepower-quattro-1200w (Wayback Machine).