Archive 1997–2024

Antec TruePower Quattro 1200W

Voltage Regulation

+3.3V regulation
Load Voltage
10% 3.33V (+0.91%)
20% 3.30V (+0%)
50% 3.27V (-0.91%)
80% 3.25V (-1.51%)
100% 3.21V (-2.73%)
110% 3.18V (-3.64%)

+3.3V is often the weakest rail with ATX-spec loads. A modern system doesn’t need many amps from this rail, but a power supply shouldn’t have problems reaching the advertised performance. In that sense, –3.64% is not the best result, but still it's still not a problem. This rail is very stable from 10-50%, after which the drop becomes larger. The load was 1.58A at 10% and 17.36A at 110%, but modern systems aren't likely to exceed ~50% load on this rail.

+5V regulation
Load Voltage
10% 5.00V (+0%)
20% 4.99V (-0.2%)
50% 4.97V (-0.6%)
80% 4.94V (-1.2%)
100% 4.92V (-1.6%)
110% 4.90V (-2%)

+5V starts at an optimal level with 5.00V. Usually we like this result to start higher, because there is often a large voltage drop under higher loads. There's not much room for a drop, but as you can see, it is still very stable. Even at 10% overload (-2%) all measurements are within the ATX specifications. The load was 1.89A on 10% and 20.83A on 110%.

+12V regulation
Load Voltage (best) Voltage (weakest)
10% 12.17V (+1.42%) 12.13V (+1.08%)
20% 12.21V (+1.75%) 12.15V (+1.25%)
50% 12.18V (+1.5%) 12.12V (+1%)
80% 12.12V (+1%) 12.07V (+0.58%)
100% 12.07V (+0.58%) 12.03V (+0.25%)
110% 12.04V (+0.33%) 12.00V (+0%)

+12V shows an untypical regulation and increases at 20% load with up to 12.21V. However, the voltage is always over 12.00V. +12V5 was always the weakest rail here but still better than most of the results we have measured in previous tests. The load was 8.65A on 10% and 94.95A on 110% (for all rails combined). By the way +12V has an OCP of 50A at all +12V rails, which is quite high.

With the OC version you can adjust the rail up to 12.6V, for those setups where one cable has to transfer very high currents with their accompanying high voltage drops. Most users will have no need of this feature, as the internal regulation is very good.

+5VSB regulation
Load Voltage
10% 5.10V (+2%)
20% 5.09V (+1.8%)
50% 5.05V (+1%)
80% 5.01V (+0.2%)
100% 4.97V (-0.6%)
110% 4.95V (-1%)

The well dimensioned +5V Standby rail starts higher than the other +5V rail. The load was 0.29A on 10% and 3.17A on 110%.

Originally published at https://www.anandtech.com/show/3807/antec-truepower-quattro-1200w (Wayback Machine).