Archive 1997–2024

350-450W Roundup: 11 Cheap PSUs

Sinan Power VP-430 430W Measurements

Voltage Regulation

+3.3V Regulation/Ripple and Noise
Load Voltage
5% 3.37V (8mV)
10% 3.37V (14mV)
20% 3.36V (24mV)
50% 3.35V (45mV)
80% FAIL
100% FAIL
110% FAIL
Crossload +12V max. FAIL
Crossload +3.3V/+5V max. FAIL

 

+5V Regulation/Ripple and Noise
Load Voltage
5% 5.11V (2mV)
10% 5.09V (15mV)
20% 5.08V (18mV)
50% 5.04V (29mV)
80% FAIL
100% FAIL
110% FAIL
Crossload +12V max. FAIL
Crossload +3.3V/+5V max. FAIL

 

+12V Regulation (Worst Ouput)/Ripple and Noise (Worst Output)
Load Voltage
5% 11.97V (6mV)
10% 11.95V (20mV)
20% 11.93V (38mV)
50% 11.87V (56mV)
80% FAIL
100% FAIL
110% FAIL
Crossload +12V max. FAIL
Crossload +3.3V/+5V max. FAIL

Noise Levels

Sound Pressure Level (Ambient: 16dBA, 1m distance) and Temperatures (Δϑ to 24.9 °C ambient temperature)
Load Opinion
5% 19 dBA (1.4°C)
10% 19 dBA (3.4 °C)
20% 24 dBA (8.5 °C)
50% 28 dBA (11.3 °C)
80% FAIL
100% FAIL
110% FAIL

Efficiency and PFC

Efficiency and Power Factor 115 VAC
Load Efficiency PFC
5% - -
10% - -
20% - -
50% - -
80% - -
100% - -
110% - -

 

Efficiency and Power Factor 230 VAC
Load Efficiency PFC
5% 56.00% 0.655
10% 66.98% 0.712
20% 73.40% 0.730
50% 74.13% 0.725
80% FAIL FAIL
100% FAIL FAIL
110% FAIL FAIL

As you can see, the PSU turned off after 50% load. All the rails are still within specification at 50%, but efficiency is low staying below 75% all the time. +12V stays stable with more than 11.87V at all tested loads, but naturally the failure at 80% load is a major black mark. PFC is as low as expected and still acceptable for a passive-PFC unit. We've seen such results quite often.