Archive 1997–2024

PC Power & Cooling Silencer 760W & 910W

Voltage Regulation

+3.3V Regulation
Load Voltage (760W / 910W)
10% +2.00% / +1.83%
20% +1.95% / +1.52%
50% +1.47% / +0.30%
80% +1.02% / -0.61%
100% +0,79% / -1.52%
110% +0.53% / -1.83%

 

+5V Regulation
Load Voltage (760W / 910W)
10% +1.34% / +0.20%
20% +1.26% / +-0.00%
50% +0.26% / -0.40%
80% -0.02% / -1.60%
100% -0.40% / -2.60%
110% -0.73% / -2.80%

 

+12V Regulation (Worst Rail)
Load Voltage (760W / 910W)
10% +2.70% / +2.33%
20% +2.51% / +2.08%
50% +1.18% / +1.00%
80% +0.67% / +0.63%
100% +0.55% / -0.25%
110% +0.23% / -0.42%

Here we can see that the 760W version is slightly better than its big brother. Well, the voltages start very high but therefore our 760W sample has hardly any voltage drop. -2.80% is the worst result we can see for the 910W PSU -- still a decent result. Everything works within the ATX specification which is nice to see.

Ripple and Noise

+3.3V Ripple Quality
Load Ripple and Noise (760W / 910W)
10% 5mV / 6mV
20% 6mV / 8mV
50% 9mV / 10mV
80% 10mV /13mV
100% 11mV / 15mV
110% 13mV / 17mV

 

+5V Ripple Quality
Load Ripple and Noise 760W / 910W
10% 9mV / 10mV
20% 12mV / 13mV
50% 18mV / 21mV
80% 22mV / 24mV
100% 24mV / 25mV
110% 25mV / 27mV

 

+12V Ripple Quality (Worst Rail)
Load Ripple and Noise 760W / 910W
10% 10mV / 19mV
20% 21mV / 23mV
50% 22mV / 26mV
80% 24mV / 28mV
100% 27mV / 32mV
110% 28mV / 34mV

In our summary we wrote that a typical PC Power & Cooling product should have low ripple & noise results. Here you are! Specially +3.3V and +12V perform very well with up to 0.29% and/or 0.34% ripple & noise (910W). The 760W model shows even better results here. On +5V we can indicate passable measurements (0.54%)

Originally published at https://www.anandtech.com/show/4441/pc-power-cooling-silencer-760w-910w (Wayback Machine).