Archive 1997–2024

HuntKey Jumper/R90 300W 80Plus Gold

Voltage Regulation and Quality

+3.3V regulation
Load Voltage
10% +1.72%
20% +1.64%
50% +1.09%
80% +0.81%
100% +0.15%
110% +0.04%

 

+5V regulation
Load Voltage
10% +2.43%
20% +2.22%
50% +1.82%
80% +1.65%
100% +1.16%
110% +0.90%

 

+12V regulation
Load Voltage best/worst
10% +1.73% / +1.91%
20% +1.66% / +1.82%
50% +1.46% /+1.61%
80% +1.24% / +1.48%
100% +1.09% / +1.30%
110% +0.84% / +1.03%

Results are measured under room temperature and 115 VAC. HuntKey has one of the best voltage regulation results out of all the high-end PSUs we've tested so far. The DC-to-DC VRMs are more than enough for the power levels listed on the label, so the voltage has low drops on +3.3V and +5V. Even +12V (V1/V2) is absolutely stable. Of course, the need to only handle 300W helps here. Some higher wattage PSUs with DC-to-DC have problems with ATX spec loads, since the VRM PCBs use almost the same dimensioning for their components.

Ripple and Noise

+3.3V ripple quality
Load Ripple and noise
10% 2mV
20% 3mV
50% 4mV
80% 6mV
100% 9mV
110% 10mV

 

+5V ripple quality
Load Ripple and noise
10% 8mV
20% 10mV
50% 13mV
80% 17mV
100% 21mV
110% 23mV

 

+12V ripple quality (worst rail)
Load Ripple and noise
10% 19mV
20% 26mV
50% 30mV
80% 22mV
100% 26mV
110% 28mV

+12V has the same problem as the first X-Series with relatively high ripple and noise results at low loads and lower results at high loads. Somewhere between these loads they change the switching type and frequency. Even so, the results are still very good and well within specification. Moreover, most manufacturers don't care about the "unimportant" 3.3V rail, but HuntKey has no more than 10 mV ripple there. Even if it's not the most important rail these days, we appreciate the attention to detail.

Originally published at https://www.anandtech.com/show/4069/huntkey-300w-80plus-gold (Wayback Machine).