1000W-1200W Roundup: Five High-End PSUs

Antec HCP-1200 Regulation

+3.3V regulation
Load Voltage
10% +0.91%
20% +0.00%
50% -0.91%
80% -1.52%
100% -2.72%
110% -3.64%

 

+5V regulation
Load Voltage
10% +0.00%
20% -0.20%
50% -0.60%
80% -1.20%
100% -1.60%
110% -2.00%

 

+12V regulation
Load best/worst
10% +1.42% / +1.08%
20% +1.50% / +1.25%
50% +1.50% / +1.00%
80% +1.00% / +0.58%
100% +0.58% / +0.25%
110% +0.33% / +0.00%

Wow! No, seriously, check out the 12V regulation. It starts just over 1% high and at 110% overload it still delivers the ideal voltage. +5V starts at the ideal and drops just 2%, which is also good. The 3.3V rail shows a more significant drop, but it's not as critical on modern systems and it's still within spec.

Ripple and Noise

+3.3V ripple quality
Load Ripple and noise
10% 8.80mV
20% 9.20mV
50% 11.50mV
80% 16.30mV
100% 19.70mV
110% 18.70mV

 

+5V ripple quality
Load Ripple and noise
10% 13.20mV
20% 15.10mV
50% 23.70mV
80% 29.20mV
100% 31.50mV
110% 35.50mV

 

+12V ripple quality
Load Ripple and noise
10% 9.90mV
20% 9.90mV
50% 13.30mV
80% 18.20mV
100% 19.70mV
110% 19.90mV

+5V shows some undershoots, which is why we see the higher results on that rail. The other rails have hardly any ripple or noise. Particularly impressive is the +12V result, with ripple always below 20mV. The oscilliscope showed very clean results with no transients.

Originally published at https://www.anandtech.com/show/3992/1000w1200w-highend-psuroundup (Wayback Machine).