1000W-1200W Roundup: Five High-End PSUs
Antec HCP-1200 Regulation
| +3.3V regulation | |
| Load | Voltage |
| 10% | +0.91% |
| 20% | +0.00% |
| 50% | -0.91% |
| 80% | -1.52% |
| 100% | -2.72% |
| 110% | -3.64% |
| +5V regulation | |
| Load | Voltage |
| 10% | +0.00% |
| 20% | -0.20% |
| 50% | -0.60% |
| 80% | -1.20% |
| 100% | -1.60% |
| 110% | -2.00% |
| +12V regulation | |
| Load | best/worst |
| 10% | +1.42% / +1.08% |
| 20% | +1.50% / +1.25% |
| 50% | +1.50% / +1.00% |
| 80% | +1.00% / +0.58% |
| 100% | +0.58% / +0.25% |
| 110% | +0.33% / +0.00% |
Wow! No, seriously, check out the 12V regulation. It starts just over 1% high and at 110% overload it still delivers the ideal voltage. +5V starts at the ideal and drops just 2%, which is also good. The 3.3V rail shows a more significant drop, but it's not as critical on modern systems and it's still within spec.
Ripple and Noise
| +3.3V ripple quality | |
| Load | Ripple and noise |
| 10% | 8.80mV |
| 20% | 9.20mV |
| 50% | 11.50mV |
| 80% | 16.30mV |
| 100% | 19.70mV |
| 110% | 18.70mV |
| +5V ripple quality | |
| Load | Ripple and noise |
| 10% | 13.20mV |
| 20% | 15.10mV |
| 50% | 23.70mV |
| 80% | 29.20mV |
| 100% | 31.50mV |
| 110% | 35.50mV |
| +12V ripple quality | |
| Load | Ripple and noise |
| 10% | 9.90mV |
| 20% | 9.90mV |
| 50% | 13.30mV |
| 80% | 18.20mV |
| 100% | 19.70mV |
| 110% | 19.90mV |
+5V shows some undershoots, which is why we see the higher results on that rail. The other rails have hardly any ripple or noise. Particularly impressive is the +12V result, with ripple always below 20mV. The oscilliscope showed very clean results with no transients.