The Enermax Liberty - Getting long in the tooth, but still worth a look
- Posted in
- Cases/Cooling/PSUs
Efficiency




Room Temperature
Since the design of the Liberty is a few years old, we didn't expect incredible results. The efficiency is not very high compared to our most recent models, though we did measure an efficiency of 81% maximum which would have been good 2 years ago. For the most part, efficiency is in the 75-80% range with loads of 20% to 80%.
Power Factor Correction

The PFC is very good at lower input voltages, while as usual we see worse results at 230VAC. Scores of .99 or higher are desirable, which the Liberty achieves on 115VAC. The 230VAC result is not unusual, and for a two year old model we won't complain too much. On higher-end PSUs we would like to see PFC break .99 at high loads even on 230VAC, but it's certainly not a bad result.
OCP Test
In the OCP test we use a function from the Chroma to see how much load each rail can take. The test puts on an additional 5A each second on the test rail until either the OCP kicks in or our Chroma will shuts down from overpowering.

The Liberty performed well on the two 12V rails. The OCP was based at the usual amount of 24A. The 3.3V rail kicked in quite early; instead of the promised 28A we could only reach 25A and at the 5V rail we could only reach 29A instead of 30A. This is not a critical flaw, however, since the performance during testing was still very good and the 12V rails tend to be much more important than the 3.3V and 5V rails.




Room Temperature
Since the design of the Liberty is a few years old, we didn't expect incredible results. The efficiency is not very high compared to our most recent models, though we did measure an efficiency of 81% maximum which would have been good 2 years ago. For the most part, efficiency is in the 75-80% range with loads of 20% to 80%.
Power Factor Correction

The PFC is very good at lower input voltages, while as usual we see worse results at 230VAC. Scores of .99 or higher are desirable, which the Liberty achieves on 115VAC. The 230VAC result is not unusual, and for a two year old model we won't complain too much. On higher-end PSUs we would like to see PFC break .99 at high loads even on 230VAC, but it's certainly not a bad result.
OCP Test
In the OCP test we use a function from the Chroma to see how much load each rail can take. The test puts on an additional 5A each second on the test rail until either the OCP kicks in or our Chroma will shuts down from overpowering.

The Liberty performed well on the two 12V rails. The OCP was based at the usual amount of 24A. The 3.3V rail kicked in quite early; instead of the promised 28A we could only reach 25A and at the 5V rail we could only reach 29A instead of 30A. This is not a critical flaw, however, since the performance during testing was still very good and the 12V rails tend to be much more important than the 3.3V and 5V rails.
Originally published at https://www.anandtech.com/show/2289 (Wayback Machine).