Cooler Master V1200 Platinum Power Supply Review
Hot Test Results
As shown in the following tables, the Cooler Master V1200 Platinum offers excellent power output quality. Our instrumentation recorded a maximum ripple of 38mV on the 12V line under maximum load, which is no small feat for a line supplying over 85 Amperes. The severe cross-loading of the voltage lines has little effect on the output stability, and it hardly affects the voltage lines any different than a very heavy balanced load. It also displays excellent voltage regulation, at 0.75%, 0.8% and 1.0% for the 3.3V, 5V and 12V line respectively.
| Main Output | ||||||||
| Load (Watts) | 242.22 W | 604.62 W | 903.35 W | 1199.57 W | ||||
| Load (Percent) | 20.18% | 50.39% | 75.28% | 99.96% | ||||
| Line | Amperes | Volts | Amperes | Volts | Amperes | Volts | Amperes | Volts |
| 3.3 V | 4.26 | 3.35 | 10.66 | 3.34 | 15.99 | 3.33 | 21.31 | 3.32 |
| 5 V | 4.26 | 5.08 | 10.66 | 5.07 | 15.99 | 5.06 | 21.31 | 5.04 |
| 12 V | 17.05 | 12.1 | 42.63 | 12.08 | 63.94 | 12.03 | 85.26 | 11.98 |
| Line | Regulation (20% to 100% load) |
Voltage Ripple (mV) | |||||
| 20% Load | 50% Load | 75% Load | 100% Load | CL1 12V |
CL2 3.3V + 5V |
||
| 3.3V | 0.75% | 12 | 16 | 18 | 20 | 14 | 22 |
| 5V | 0.8% | 16 | 18 | 20 | 24 | 14 | 26 |
| 12V | 1% | 12 | 22 | 30 | 38 | 34 | 18 |
High ambient temperatures have little impact on the performance of the Cooler Master V1200 Platinum, even smaller than that of the almost identical SS-1200XP3. The average nominal load (20-100%) efficiency drops to 93.0% and the maximum efficiency is 94.1% at 50% load. Technically, this unit would maintain its 80 Plus Platinum certification even if the test took place with an ambient temperature of >45°C. (Note that the 80 Plus certification tests take place with an ambient temperature of 25°C.)
As expected, the cooling system maintains a similar profile with the PSU inside the hot box -- the higher ambient temperatures just make it even more aggressive. The fan once again starts at 20% load, but the speed of the fan is now rapidly increasing as soon as the load increases any further. Even at 50% load, our instrumentation was reading over 44dB(A), a sound pressure level that would surely be rated as uncomfortable by the vast majority of consumers. If the load is over 800 Watts for prolonged periods of time, the sound pressure level goes over 50dB(A), creating a hostile environment for any typical consumer/commercial users.