Archive 1997–2024

Seagate's Intel Rangeley NAS Pro 4-bay Review

Single Client Performance - CIFS and NFS on Linux

A CentOS 6.2 virtual machine was used to evaluate NFS and CIFS performance of the NAS when accessed from a Linux client. We chose IOZone as the benchmark for this case. In order to standardize the testing across multiple NAS units, we mount the CIFS and NFS shares during startup with the following /etc/fstab entries.

//<NAS_IP>/PATH_TO_SMB_SHARE /PATH_TO_LOCAL_MOUNT_FOLDER cifs rw,username=guest,password= 0 0

<NAS_IP>:/PATH_TO_NFS_SHARE /PATH_TO_LOCAL_MOUNT_FOLDER nfs rw,relatime,vers=3,rsize=32768,wsize=32768,namlen=255,hard,proto=tcp,timeo=600,retrans=2, sec=sys,mountaddr <NAS_IP>,mountvers=3,mountproto=udp,local_lock=none,addr=<NAS_IP> 0 0

The following IOZone command was used to benchmark the CIFS share:

IOZone -aczR -g 2097152 -U /PATH_TO_LOCAL_CIFS_MOUNT -f /PATH_TO_LOCAL_CIFS_MOUNT/testfile -b <NAS_NAME>_CIFS_EXCEL_BIN.xls > <NAS_NAME>_CIFS_CSV.csv

IOZone provides benchmark numbers for a multitude of access scenarios with varying file sizes and record lengths. Some of these are very susceptible to caching effects on the client side. This is evident in some of the graphs in the gallery below.

Readers interested in the hard numbers can refer to the CSV program output here.

The NFS share was also benchmarked in a similar manner with the following command:

IOZone -aczR -g 2097152 -U /nfs_test_mount/ -f /nfs_test_mount/testfile -b <NAS_NAME>_NFS_EXCEL_BIN.xls > <NAS_NAME>_NFS_CSV.csv

The IOZone CSV output can be found here for those interested in the exact numbers.

A summary of the bandwidth numbers for various tests averaged across all file and record sizes is provided in the table below. As noted previously, some of these numbers are skewed by caching effects. A reference to the actual CSV outputs linked above make the entries affected by this effect obvious.

Seagate NAS Pro 4-bay - Linux Client Performance (MBps)
IOZone Test CIFS NFS
Init Write 66 64
Re-Write 67 70
Read 31 117
Re-Read 31 121
Random Read 19 55
Random Write 62 70
Backward Read 18 43
Record Re-Write 771* 1173*
Stride Read 28 101
File Write 64 74
File Re-Write 67 76
File Read 22 89
File Re-Read 22 90
*: Benchmark number skewed due to caching effect

 

Originally published at https://www.anandtech.com/show/8404/seagate-intel-rangeley-nas-pro-4bay-review (Wayback Machine).