Corsair CX430 V2 430W Measurements
Voltage Regulation
| +3.3V Regulation/Ripple and Noise | |
| Load | Voltage |
| 5% | 3.29 V (3mV) |
| 10% | 3.27 V (3mV) |
| 20% | 3.27 V (4mV) |
| 50% | 3.25 V (5mV) |
| 80% | 3.25 V (6mV) |
| 100% | 3.22 V (7mV) |
| 110% | 3.20 V (13mV) |
| Crossload +12V max. | -1.52% |
| Crossload +3.3V/+5V max. | -3.64% |
| +5V Regulation/Ripple and Noise | |
| Load | Voltage |
| 5% | 5.10 V (4mV) |
| 10% | 5.10 V (6mV) |
| 20% | 4.99 V (5mV) |
| 50% | 4.97 V (5mV) |
| 80% | 4.96 V (7mV) |
| 100% | 4.95 V (7mV) |
| 110% | 4.92 V (8mV) |
| Crossload +12V max. | -0.60% |
| Crossload +3.3V/+5V max. | -5.80% |
| +12V Regulation (Worst Ouput)/Ripple and Noise (Worst Output) | |
| Load | Voltage |
| 5% | 12.01 V (8mV) |
| 10% | 11.98 V (9mV) |
| 20% | 11.98 V (10mV) |
| 50% | 11.95 V (12mV) |
| 80% | 11.92 V (15mV) |
| 100% | 11.89 V (18mV) |
| 110% | 11.88 V (22mV) |
| Crossload +12V max. | -3.50% |
| Crossload +3.3V/+5V max. | -0.25% |
Noise Levels
| Sound Pressure Level (Ambient: 16dBA, 1m distance) and Temperatures (Δϑ to 23.4 °C ambient temperature) | |
| Load | Opinion |
| 5% | 17 dBA (1.0°C) |
| 10% | 17 dBA (1.9 °C) |
| 20% | 18 dBA (3.9 °C) |
| 50% | 22 dBA (6.4 °C) |
| 80% | 25 dBA (9.1 °C) |
| 100% | 27 dBA (10.5 °C) |
| 110% | 27 dBA (11.4 °C) |
Efficiency and PFC
| Efficiency and Power Factor 115 VAC | ||
| Load | Efficiency | PFC |
| 5% | 69.48% | 0.810 |
| 10% | 73.90% | 0.919 |
| 20% | 81.64% | 0.927 |
| 50% | 83.29% | 0.951 |
| 80% | 82.88% | 0.968 |
| 100% | 82.05% | 0.974 |
| 110% | 81.71% | 0.981 |
| Efficiency and Power Factor 230 VAC | ||
| Load | Efficiency | PFC |
| 5% | 69.97% | 0.795 |
| 10% | 75.12% | 0.890 |
| 20% | 82.15% | 0.902 |
| 50% | 84.90% | 0.931 |
| 80% | 83.79% | 0.961 |
| 100% | 82.90% | 0.971 |
| 110% | 82.43% | 0.975 |
The sound pressure level and found out, that this PSU has a good fan speed regulation. The RPMs are tolerable up to 50-80% load. Beyond that point, this PSU is no longer silent, but still quiet enough. Note the difference the power grid makes in terms of efficiency. 115VAC means higher current and more stress for all power supplies, while 230VAC shows a worse power factor at all loads. Nevertheless, 0.975 PFC is still good and most users will find 83% efficiency more than sufficient. All the rails fall clearly within ATX specifications.
Originally published at https://www.anandtech.com/show/6013/350450w-roundup-11-cheap-psus (Wayback Machine).