PC Power & Cooling Silencer Mk III 400W
Voltage Regulation
| +3.3V Regulation/Ripple and Noise | |
| Load | Voltage |
| 5% | +2.06% (3mV) |
| 10% | +1..94% (5mV) |
| 20% | +1.79% (5mV) |
| 50% | +0.39% (6mV) |
| 80% | -0.91% (10mV) |
| 100% | -1.67% (15mV) |
| 110% | -1.85% (17mV) |
| Crossload +12V max. | +1.15% |
| Crossload +3.3V/+5V max. | +0.60% |
| +5V Regulation/Ripple and Noise | |
| Load | Voltage |
| 5% | +1.56% (4mV) |
| 10% | +1.44% (5mV) |
| 20% | +1.12% (5mV) |
| 50% | -0.32% (8mV) |
| 80% | -1.74% (12mV) |
| 100% | -1.92% (15mV) |
| 110% | -2.02% (16mV) |
| Crossload +12V max. | +2.36% |
| Crossload +3.3V/+5V max. | -5.25% |
| +12V Regulation (Worst Ouput)/Ripple and Noise (Worst Output) | |
| Load | Voltage |
| 5% | +1.58% (4mV) |
| 10% | +1.54% (4mV) |
| 20% | +2.06% (4mV) |
| 50% | +1.88% (7mV) |
| 80% | +1.73% (9mV) |
| 100% | +1.31% (10mV) |
| 110% | +1.18% (11mV) |
| Crossload +12V max. | -0.90% |
| Crossload +3.3V/+5V max. | +4.92% |
Noise Levels
| Loudness and Temperatures (Δϑ to 22.5 °C ambient temperature) | |
| Load | Opinion |
| 5% | small fan noise (1.1 °C) |
| 10% | small fan noise (1.9 °C) |
| 20% | small fan noise (3.7 °C) |
| 50% | small fan noise and choke chirping (5.8 °C) |
| 80% | fan noise and choke chirping (9.9 °C) |
| 100% | strong fan noise and choke chirping (12.3 °C) |
| 110% | strong fan noise and choke chirping (13.4 °C) |
Efficiency and PFC
| Efficiency and Power Factor 115 VAC | ||
| Load | Efficiency | PFC |
| 5% | 70.69% | 0.843 |
| 10% | 75.80% | 0.945 |
| 20% | 82.24% | 0.957 |
| 50% | 86.20% | 0.989 |
| 80% | 84.08% | 0.991 |
| 100% | 83.76% | 0.993 |
| 110% | 83.39% | 0.993 |
| Efficiency and Power Factor 230 VAC | ||
| Load | Efficiency | PFC |
| 5% | 71.47% | 0.724 |
| 10% | 79.22% | 0.877 |
| 20% | 82.70% | 0.952 |
| 50% | 86.71% | 0.988 |
| 80% | 85.59% | 0.992 |
| 100% | 84.80% | 0.993 |
| 110% | 84.16% | 0.992 |
The lower voltage rails drop slightly more than 1.80% below the ideal value, while the 12V rail stays very close to what ATX specification requires. These voltage drops will not cause any problem at all when this PSU is in use in a system. The same is true for the ripple & noise results as this PSU has less than20mV on all outputs. One problem is the poor crossload performance since +5V and +12V are connected to the same feedback. With 230VAC input, the Silencer Mk III 400W starts at 70% efficiency loaded with 20W. It reached a maximum efficiency of 87% at medium load. Efficiency is somewhat lower with 115VAC, reaching up to 86% during 50% load. However, PC Power & Cooling is able to stay above the values they need for 80Plus Bronze. As hoped for the fan is quiet under low load. The choke chirping and fan noise at higher loads make the product a bit of unattractive.