Archive 1997–2024

Visiting FSP + Aurum CM 750W Preview

Voltage Regulation

+3.3V Regulation
Load Voltage
10% +1.58%
20% +1.21%
50% +0.15%
80% -1.06%
100% -1.61%
110% -2.27%

 

+5V Regulation
Load Voltage
10% +0.74%
20% +0.46%
50% -0.30%
80% -1.10%
100% -1.70%
110% -2.04%

 

+12V Regulation (Worst Rail)
Load Voltage
10% +1.01%
20% +0.81%
50% +0.19%
80% -0.35%
100% -0.77%
110% -0.96%

First we take a look at the voltage regulation. All rails start relatively close to their optimal values. +3.3V and +5V reached about -2% during overload which is decent. The four +12V rails show even better results. Even the worst rail stays over -1% at highest load. FSP has btw. no problems with dynamic loads. We saw some tests from 50Hz to 10KHz where the load current decreased after a small duration with satisfying voltage results.

Ripple and Noise

+3.3V Ripple Quality
Load Ripple and Noise
10% 26mV
20% 23mV
50% 31mV
80% 38mV
100% 42mV
110% 44mV

 

+5V Ripple Quality
Load Ripple and Noise
10% 18mV
20% 18mV
50% 21mV
80% 30mV
100% 40mV
110% 46mV

 

+12V Ripple Quality (Worst Rail)
Load Ripple and Noise
10% 30mV
20% 32mV
50% 45mV
80% 72mV
100% 97mV
110% 116mV

These ripple & noise measurements tell us that this Gold series was planed as an affordable offer while most other 80Plus Gold PSUs show better results -- for much higher prices. +5V and +12V are very close to 1% ripple & noise. However all rails are within ATX specification and most PC systems shouldn't reach 100% load or more. Those results from the +3.3V rail with 26mV at low load and 23mV at a higher load are very unusual.

Originally published at https://www.anandtech.com/show/4439/visiting-fsp-aurum-cm-750w-preview (Wayback Machine).