Archive 1997–2024

550W Roundup: Three PSUs at Different Prices

Antec Voltage Regulation and Quality

+3.3V regulation
Load Voltage
10% 3.41V (+3.33%)
20% 3.41V (+3.33%)
50% 3.39V (+2.73%)
80% 3.37V (+2.12%)
100% 3.36V (+1.81%)
110% 3.36V (+1.81%)

 

+5V regulation
Load Voltage
10% 5.16V (+3.2%)
20% 5.15V (+3.0%)
50% 5.13V (+2.60%)
80% 5.10V (+2.00%)
100% 5.09V (+1.8%)
110% 5.08V (+1.6%)

 

+12V regulation
Load Voltage best/worst
10% 12.18V (+1.50%) / 12.17V (+1.42%)
20% 12.17V (+1.42%) / 12.16V (+1.33%)
50% 12.12V (+1.00%) / 12.10V (+0.83%)
80% 12.08V (+0.66%) / 12.05V (+0.42%)
100% 12.05V (+0.42%) / 12.01V (+0.08%)
110% 12.03V (+0.25%) / 12.00V (+0.00%)

All +12V show almost the same performance and still stay above 12.00V at 110% load.+3.3V starts very high and reaches 3.36V at full load. The same goes for the +5V rail, which starts with +3.2% and ends at +1.6%.

Ripple and Noise

+3.3V ripple quality
Load ripple and noise
10% 4.70mV
20% 5.50mV
50% 7.20mV
80% 9.30mV
100% 9.70mV
110% 10.90mV

 

+5V ripple quality
Load ripple and noise
10% 7.30mV
20% 8.00mV
50% 9.30mV
80% 10.80mV
100% 13.30mV
110% 15.20mV

 

+12V ripple quality
Load ripple and noise
10% 7.90mV
20% 10.10mV
50% 13.80mV
80% 19.60mV
100% 21.30mV
110% 33.70mV

Holy moly! All of the rails have no remarkable transients and ripple is always below 50% of the allowed level. +3.3V only just exceeds 10mV (at 110%), which is impressive. Overall, these are exceptional results and deserve praise; we wish every manufacturer would do as well!

Originally published at https://www.anandtech.com/show/3985/three-550w-psus-for-different-prices (Wayback Machine).