The Single 12V Rail SilverStone Olympia OP650
- Posted in
- Cases/Cooling/PSUs
230VAC 3.3V, 5V, and 5Vsb Tests
This is the same test we ran earlier only using 230VAC. Since the power supply just came out of its box fresh and unused when we ran these tests, the results might look a little better than the ones with 115VAC. Still, the lower voltages like 3.3 and 5V dropped significantly and went under the spec limit at higher loads. This would not be acceptable in a real system, as it would not work properly after the voltage dropped that much. Of course, our test setup does represent a worst case scenario, as most users will not run with temperatures as high as we do.



This is the same test we ran earlier only using 230VAC. Since the power supply just came out of its box fresh and unused when we ran these tests, the results might look a little better than the ones with 115VAC. Still, the lower voltages like 3.3 and 5V dropped significantly and went under the spec limit at higher loads. This would not be acceptable in a real system, as it would not work properly after the voltage dropped that much. Of course, our test setup does represent a worst case scenario, as most users will not run with temperatures as high as we do.



Originally published at https://www.anandtech.com/show/2275 (Wayback Machine).